Item | Performance characteristics |
---|---|
Connectable Safety Light Curtains | Safety light curtain manufactured by Panasonic Industrial Devices SUNX |
Applicable Standards: International Standard | IEC 61496-1 (Type 4) |
CE Marking Directive Compliance | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
Applicable Standards: Japan | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
Applicable Standards: Europe (EU) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11 and SF-C13 comply with UL 1998 (Class 2).) |
Applicable Standards: North America | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11 and SF-C13 comply with UL 1998 (Class 2).) |
Power Voltage | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
Current Consumption | 100 mA or less (without light curtain) |
Fuse Rating | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
Safety Output | NO contact × 3 (13-14, 23-24, 33-34) |
Safety Output: Application Category | AC-15, DC-13 (IEC 60947-5-1) |
Safety Output: Rated Operation Voltage (Ue)/Rated Operation Current (le) | 4 A / 30 V DC, 4 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC) (Note:If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |
Safety Output: Contact Material/Contacts | AgSnO, self cleaning, positively driven |
Safety Output: Contact Resistance | 100 mOhm or less (initial value) |
Safety Output: Contact Protection Fuse Rated | 4 A (slow blow) |
Safety Output: Mechanical Lifetime | 10,000,000 times or more (open/close frequency of 180 times/min) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Safety Output: Electrical Lifetime | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Pick-Up Delay (Auto Reset/Manual Reset) | 80 ms or less / 90 ms or less |
Response Time | 10 ms or less |
Auxiliary Outputs | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
Auxiliary Output: Rated Operation Voltage / Current | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
Auxiliary Output: Contact Protection Fuse Rated | 2 A (slow blow) |
Semiconductor Auxiliary Output (Aux) | PNP open-collector transistor ・Max. source current: 60 mA ・Applied voltage: same as supply voltage (between the semiconductor auxiliary output and +V) ・Residual voltage: 2.3 V or less (at source current 60 mA) Leakage current: 2 mA or less |
Semiconductor Auxiliary Output (Aux): Output Operation | On when the safety light curtain is interrupted |
Overvoltage Category | II |
Indicators: Power Supply (Ui) | Green LED (lights up when the power is ON) |
Indicators: Safety Output [OUT] | Green LED (lights up when safety output is closed) (Note:The operation indicator is marked as "Enabling" on the unit for SF-C12.) |
Indicators: Interlock | Yellow LED (lights up when enabling contacts are opened) |
Indicators: Fault (Fault) | Yellow LED (blinks when fault occurs) |
External Relay Monitor Function | Incorporated |
Trailing Edge Function | Incorporated |
Polarity Selection Function | Incorporated (Cable connection allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain (Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
Pollution Degree | 2 |
Environmental Resistance: Degree of Protection | Enclosure: IP40 Terminal: IP20 |
Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158℉ |
Ambient Humidity | 30 to 85 % RH, Storage: 30 to 95 % RH |
Vibration Resistance | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, and Z directions for twenty times each |
Enclosure Material | ABS |
Connection Terminal | Spring-cage terminal |
Weight (Typ.) | Net weight: 200 g approx. |
품명 | 상품페이지 참고 |
---|---|
모델명 | 상품페이지 참고 |
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 | 상품페이지 참고 |
제조국 또는 원산지 | 상품페이지 참고 |
제조자 | 상품페이지 참고 |
A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 | 상품페이지 참고 |
사용후기가 없습니다.
상품문의가 없습니다.
※ 배송지역 : 전국(제주 및 섬지역, 기타 산간/도서지역 포함)
※ 배송기간 : 15시 이전 결제 확인 후 당일 로젠 또는 경동 택배로 발송됩니다.
(단 입고예정 상품과 수입상품 및 주문량이 폭주하는 상품의 경우는 배송이 지연될 수 있습니다.)
※ 배송요금 : 선불/후불 선택
- 교환/반품시 상품 수령일로부터 7일 이내에 전화 요청해 주시기 바랍니다.(상품수령일포함) 041-558-7161
※ 반품/교환/불가사유
- 다음의 경우에는 반품/교환이 불가 합니다.
* 상품 구매시 부주의로 인한 오 주문건의 경우
* 상품 및 구성품을 취급부주의로 인한 파손/고장/오염된 경우
* 고객님의 요청에 의해 주문제작된 경우 고객님의 변심에 의한 경우
* 상품을 설치하였거나 사용 또는 상품 일부를 소비하였을 경우
* 고객님의 책임있는 사유로 상품 등이 멸실 또는 훼손된 경우
* 상품을 개봉 또는 장착 또는 사용하였을 경우
* 중고 상품의 기능상 문제가 없을 경우
* 반품/교환 가능기간을 초과하였을 경우 (상품 수령일 기준 7일 이내)
- 교환/반품시 상품에는 훼손및 변형이 없어야 반품가능합니다. (신품에 한함)
- 교환/반품시 판매자가 이용하는 경동 택배을 이용하셔야만 신속하게 처리됩니다.
- 교환/반품 택배비 미동봉인 경우 [[계좌번호: 신한은행 100-034-266794 예금주: (주)울트라이노베이션]] 로 입금후 게시판 또는 저희
(주)울트라이노베이션 TEL: 041-558-7161~3 로 문의 주시면 확인 후 빠른 처리 하도록 하겠습니다.
- 반드시, 구매자이신 고객님의 이름과 동일한 입금자명으로 입금해 주시기 바랍니다.
충남 아산시 번영로 111 (온천동)
전화 041-558-7161~3 / 팩스 041-557-7161
E-mail plc7161@ultrai.co.kr
운영시간안내
평일 09 : 00 ~ 18 : 00
(토요일, 일요일, 공휴일 휴무)