| range of product | Preventa Safety automation |
|---|
| product or component type | Preventa safety module |
|---|
| safety module name | XPSAF |
|---|
| safety module application | For emergency stop and switch monitoring |
|---|
| function of module | Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard |
|---|
| safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach category 3 conforming to EN/IEC 62061 |
|---|
| safety reliability data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 243 years conforming to EN/ISO 13849-1 PFHd = 4.62E-9 1/h conforming to EN/IEC 62061 |
|---|
| type of start | Configurable |
|---|
| connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
|---|
| output type | Relay instantaneous opening, 3 NO circuit(s), volt-free |
|---|
| number of additional circuits | 0 |
|---|
| [Us] rated supply voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |
|---|